    摘要:

    针对参考时钟源高电平脉冲宽度窄(小于2 ns)和本底噪声大的问题,通过使用一种时钟低抖动整形技术方案,使参考时钟经过锁相整形后高电平脉冲宽度大于3 ns、锁相相位时间抖动均方根(RMS)值小于5 ps。目前该方案已成功用于星光III激光装置的联机实验,情况良好,对其他类似需要精密时钟的装置具有极大的借鉴意义。

    Abstract:

    A low jitter clock shaping scheme is proposed, which solves the problem of high pulse with narrow width(less than 2 ns) and large noise floor of the reference clock source. The technical specifications achieved are the high reference clock pulse width greater than 3 ns, phase-locked phase jitter Root Mean Square(RMS) less than 5 ps after Phase Locked Loop(PLL). And the signal integrity simulation design verification is further realized through the Input/Output Buffer Information Specification (IBIS) model. At present, the scheme has been successfully used in online experiment of XG-III laser device and is in good condition. It is of great reference to the accurate implementation of the synchronization system of radiation sources in different frequency bands.