Nondestructive testing of MCS dielectric defect based on A-Scan and C-Scan of Ultrasonic Test
Author:
Affiliation:

Funding:

Ethical statement:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
    Abstract:

    Ultrasonic Test(UT) technology for dielectric defects of Multilayer Ceramic Structure(MCS) is studied. Firstly, UT is proved to be applicable and effective to voids and delamination through thin layer reflections theoretical calculating on Multi-Layer Ceramic Capacitors(MLCC) structure, as low UT frequency can get very strong reflection signal at extremely thin aperture. Simultaneously, suggestion of C-Scan testing parameters including equivalent focal length, surface wave time, data gate and gain is given. Then, the practical UT test of MCS indicates that 50 MHz is the optimum screening frequency. Finally, defect determining and locating is accomplished via A-Scan and transit time respectively, the conclusion is also verified by sectioned UT sample preparation and detection.

    Reference
    Related
    Cited by
Get Citation

何志刚,梁栋程,龚国虎,王晓敏.基于A-Scan和C-Scan的多层陶瓷结构介质缺陷无损检测[J]. Journal of Terahertz Science and Electronic Information Technology ,2020,18(5):951~955

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
History
  • Received:February 23,2019
  • Revised:May 23,2019
  • Adopted:
  • Online: November 02,2020
  • Published: